(42U/47U60)server rack SPEEDSMOUNT equipment storage IT network cabinet data center equipment storage

$899.00 SGD
SKU: 42U60
Availability: In Stock Pre order Out of stock
Description
Very important :
Please check your ceiling height and hallway width before ordering this server rack  as they are shipped pre-assembled.

 

Video

ALL

https://youtube.com/shorts/w_EsYTpDt60

42U 60*60 

https://youtube.com/shorts/IKCsrykhYSc

https://youtube.com/shorts/bv1RDVbbgMw

https://youtube.com/shorts/FihsLlCKj_o

42U 60*80 

https://youtube.com/shorts/WUwOjPqbnww

42U 60*100

https://youtube.com/shorts/kAq_HbVp768

https://youtube.com/shorts/w_EsYTpDt60

https://www.youtube.com/shorts/FihsLlCKj_o

https://www.youtube.com/shorts/_VFphjPr2Nc

42U   IP20
steel 1 mm, pole 1.8 mm size 200cm*60*60cm  SGD759 assembled.

60cm depth price include 2 fans and 3 shelves

 

steel 1 mm, pole 1.8 mm size 200cm*60*80cm  SGD799  assembled.

price include 2 fans and 3 shelves

 

steel 1.2 mm, pole 2 mm size 200cm*60*100cm  SGD899 assembled.

80cm and 100cm depth price include 4 fans and 3 shelves

Delivery add SGD 50-80 based on address and whether need to carry. lift

extra shelf ADD SGD 29-39

extra fan SG 18

extra patch panel SGD 50

extra PDU SGD 39

Metal mesh front and back  door. 

 

 

42U Server Rack Configuration FAQ

Q1: What is a 42U server rack, and how much equipment can it hold?
  • Height Standard: 1U equals 4.445 cm (1.75 inches).
  • Physical Capacity: A 42U rack provides 186.7 cm (73.5 inches) of usable vertical space.
  • Equipment Limit: It can theoretically hold up to 42 single-U (1U) device

Q2: What type of network and IT equipment can be installed in a 42U rack?
  • Compute & Storage: Rackmount servers, Network Attached Storage (NAS).
  • Networking & Security: Network switches, hardware firewalls, load balancers.
  • Cable Management: Patch panels, horizontal/vertical cable managers.
  • Power Systems: Uninterruptible Power Supplies (UPS), Power Distribution Units (PDUs).


Q3: How should I layout these devices vertically inside the 42U rack?
For optimal stability, airflow, and cabling, install equipment from the bottom up:
  • Bottom (U1 - U6): Heaviest equipment. Place UPS battery packs and large NAS storage here.
  • Middle (U7 - U32): Core computing. Place servers here (heavier servers lower down).
  • Upper Middle (U33 - U38): Network core. Place firewalls, load balancers, and switches.
  • Top (U39 - U42): Patching & power. Place patch panels and horizontal PDUs (if not vertically mounted).



Q4: How should switches and patch panels be arranged together?
  • Alternating Layout: Use a "Patch Panel - Switch - Patch Panel" sandwich pattern.
  • Benefit: This allows short patch cords to connect directly, minimizing cable clutter across the rack.


Q5: Where is the best place to install the PDU (Power Distribution Unit)?
  • Horizontal Mounting: Consumes 1U or 2U of space, usually placed at the very top or in the middle of dense server zones.
  • Vertical Mounting (0U): Attaches to the rear sides of the rack, using zero vertical rack units. (Highly recommended to save space for servers).



Q6: Why must the UPS be installed at the very bottom of the rack?
  • Center of Gravity: UPS units and battery packs are extremely heavy. Placing them at the bottom prevents the rack from becoming top-heavy and tipping over.
  • Maintenance: It makes heavy-duty rail installation safer and simplifies future unit replacements.


Q7: What other key factors should I consider when populating a 42U rack?

  • Weight Limit: Verify the rack's weight capacity (e.g., 800 kg or 1000 kg) against the total weight of your gear.
  • Airflow Management: Use blanking panels in empty U spaces to prevent hot air from recycling back into the equipment.
  • Rack Depth: Ensure the rack depth (e.g., 1000mm or 1200mm) accommodates deep servers and leaves room for rear cable clearance.